INDUSTRIAL COMBUSTION ANALYSERS
This range of gas analysers is built is built around 4 models that can measure with upto 6 electrochemical sensors and 3 NDIR sensors for pollution.
Applications
- Boilers: Utility & Power plants Industrial boilers
Heaters & Dryers: Paint, Textile, Food, Paper, Rubber, etc. Process heaters
Kilns / Furnaces: Cement, Lime, Glass, Ceramic
Stationary internal combustion engines: Gas compression, UPS power cogeneration, Oil fired pumping station
Turbines
Chemical analysis laboratory: Fuel additive
CEM backup & maintenance
ISO 14000: Auditing, Compliance
SPECIFICATIONS | ||||||||
Parameter | Sensor | Range | Resol. | Acuracy | ||||
O2 | Electrochimical | 0 ‐25% | 0.1% | ±0.1% vol | ||||
CO | Electrochimical | 0 ‐8000 ppm | 1 ppm | ±10 ppm <300 ppm | ||||
H2 <2000ppm comp | ±4% upto 2000 ppm | |||||||
10% >2000 ppm | ||||||||
NOx | Calculated | 0 ‐5000 ppm | 1 ppm | |||||
CO2 | Calculated | 0 ‐99.9% | 0.1% | |||||
T air | Pt100 | ‐10 ‐99.9°C | 0.1°C | ±(0.2% Rdg + 0.15°C) | ||||
T gas | Tc K | 0 ‐999.9°C | 0.1°C | ±(0.3% Rdg + 0.3°C) | ||||
∆ T | Calculated | 0 ‐999.9°C | 0.1°C | |||||
Pressure/Draft | Pont | ±100.00hPa | 1hPa | ±3Pa < 300Pa | ||||
±1% Rdg. >300Pa | ||||||||
Excess Air | Calculated | 1.00 ‐infinity | 0.01 | |||||
Efficiency | Calculated | 1 ‐99.9% | 0.1% | |||||
Smoke Index | Paper Filter method | 0 ‐9 Bacharach | ||||||
! All emissions measurements are available also with a programmable O2 reference value. | ||||||||
! NOx concentration can be shown in terms of stack equivalent NO2 | ||||||||
! Accuracy limits are stated as % of reading. Additional ±1 digit error has to be considered. | ||||||||
! The pressure accuracy shown is valid only after zero procedure. | ||||||||
! Measuring readings can be directly converted from ppm to mg/Nm3 , from hPa to mbar, mmH2 O, inH2 O and from °C to °F | ||||||||